DragonFly On-Line Manual Pages
tntnet.properties(7) Tntnet users guide tntnet.properties(7)
NAME
tntnet.properties - configuration-file for tntnet (8)
DESCRIPTION
tntnet(8) uses cxxtools for logging and is configured in the
configuration-file tntnet.properties.
Because cxxtools is a meta-logging-library, which can be compiled to
use different logging-libraries, the content of tntnet.properties is
dependend of the underlying logging-library. Cxxtool has a built-in
logging-library as default, which is documented here.
format
The format of tntnet.properties is line-based. A line consists of a
variable-name followed by a equals-symbol and a value. Lines, which
does not follow this format and lines, which start with a hash (#), are
ignored. It is recomended to prefix non-empty comments with a hash to
make clear, that it is a comment.
level
The logging-library has 5 levels for logging: fatal, error, warn, info
and debug. Fatal has the highers priority and "debug" the lowest.
category
Each log-message has a category. Categories are hierarchical. Names
of subcategories are devided by a dot.
log-message
Each log-message has a level and a category. If the level of the
message is higher or equal to the level of the category, the message is
logged. To assign a level to a category put a line with the word
"logger", a dot, the category, the symbol "=" and the category into
tntnet.properties. Only the first letter of the value is checked and
case is ignored, so e.g. info can be specified with INFO, info, I or
even ixxxx. If no level is specified for the current category, the
upper category is checked. If nothing is found, the default level is
used. The default level is specified by the variable "rootLogger". If
no rootLogger is specified, the level error is used.
destination
If nothing else is specified, log-messages are printed to standard-
output. To redirect output to a file, specify the filename with the
variable file.
The cxxtools-logger can limit the size of the log-file by rolling log-
files. If the limit is reached, the current file is renamed by
appending ".1" to it. If there is already a file with that name, this
file is renamed to "*.2" and so on, until the maximum backupfile limit
is reached. The oldest file is deleted then. To specify the maximum
file size, set the variable maxfilesize. The value specified here can
be postfixed with 'k' or 'M' to specify kBytes or MBytes. The maximum
fileindex backed up is set with maxbackupindex.
Log-messages can be sent to another host in the network with udp. This
is done by specifying a hostname and a port with the variable host.
The value must be a hostname, followed by a ':' and a port. Each log-
message is sent in a single udp-message.
EXAMPLES
logging to standard-output:
rootLogger=INFO
logger.tntnet=WARN
logging to a file with rolling file and a background-flusher:
rootLogger=INFO
logger.tntnet=WARN
file=tntnet.log
maxfilesize=1MB
maxbackupindex=10
logging to another host
rootLogger=INFO
logger.tntnet=WARN
host=pluto.tntnet.org:1234
AUTHOR
This manual page was written by Tommi Makitalo <tommi@tntnet.org>.
SEE ALSO
tntnet(8)
Tntnet 2006-08-13 tntnet.properties(7)