DragonFly On-Line Manual Pages

Search: Section:  


MODBUS_RTU_GET_RTS(3)          Libmodbus Manual          MODBUS_RTU_GET_RTS(3)

NAME

modbus_rtu_get_rts - get the current RTS mode in RTU

SYNOPSIS

int modbus_rtu_get_rts(modbus_t *ctx);

DESCRIPTION

The modbus_rtu_get_rts() function shall get the current Request To Send mode of the libmodbus context ctx. The possible returned values are: o MODBUS_RTU_RTS_NONE o MODBUS_RTU_RTS_UP o MODBUS_RTU_RTS_DOWN This function can only be used with a context using a RTU backend.

RETURN VALUE

The modbus_rtu_get_rts() function shall return the current RTS mode if successful. Otherwise it shall return -1 and set errno.

ERRORS

EINVAL The libmodbus backend is not RTU.

SEE ALSO

modbus_rtu_set_rts(3)

AUTHORS

The libmodbus documentation was written by Stephane Raimbault <stephane.raimbault@gmail.com[1]>

NOTES

1. stephane.raimbault@gmail.com mailto:stephane.raimbault@gmail.com libmodbus 3.1.0 10/06/2013 MODBUS_RTU_GET_RTS(3)