DragonFly On-Line Manual Pages

Search: Section:  


mDI001(3)                    One-Wire File System                    mDI001(3)

NAME

mDI001 - Digital Input Module

SYNOPSIS

Monitor 4 digital lines A5 [.]XXXXXXXXXXXX[XX][/[ switch_closed.[0-3|ALL|BYTE] | loop_open.[0-3|ALL|BYTE] | loop_shorted.[0-3|ALL|BYTE] | See the file man3/standard_mini.3so. ]]

FAMILY CODE

A5

SPECIAL PROPERTIES

switch_closed.[0-3|ALL|BYTE] read-only, yes-no Is the relay closed? (1=yes, 0=no). Note that OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4. loop_shorted.[0-3|ALL|BYTE] read-only, yes-no Is the loop shorted? (1=yes, 0=no). Failsafe mode. Note that OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4. loop_open.[0-3|ALL|BYTE] read-only, yes-no Is the loop open? (1=yes, 0=no). Failsafe mode. Note that OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4.

STANDARD PROPERTIES

See the file man3/standard.3so.

ALARMS

None.

DESCRIPTION

See the file man3/description.3so. mDI001 The mDI001 (3) is used to monitor digital lines for simple switching.

ADDRESSING

See the file man3/addressing.3so.

WEBSITE

http://www.cmciel.com/products-solutions/individual-products/4-channel- fail-safe-digital-module-mdi001/ See the file man3/seealso.3so.

AVAILABILITY

http://www.owfs.org

AUTHOR

Paul Alfille (paul.alfille@gmail.com) OWFS Manpage 2003 mDI001(3)