DragonFly On-Line Manual Pages
mDI001(3) One-Wire File System mDI001(3)
NAME
mDI001 - Digital Input Module
SYNOPSIS
Monitor 4 digital lines
A5 [.]XXXXXXXXXXXX[XX][/[ switch_closed.[0-3|ALL|BYTE] |
loop_open.[0-3|ALL|BYTE] | loop_shorted.[0-3|ALL|BYTE] |
See the file man3/standard_mini.3so.
]]
FAMILY CODE
A5
SPECIAL PROPERTIES
switch_closed.[0-3|ALL|BYTE]
read-only, yes-no
Is the relay closed? (1=yes, 0=no).
Note that OWFS uses 0 through 3 as the index and the datasheet uses 1
through 4.
loop_shorted.[0-3|ALL|BYTE]
read-only, yes-no
Is the loop shorted? (1=yes, 0=no). Failsafe mode.
Note that OWFS uses 0 through 3 as the index and the datasheet uses 1
through 4.
loop_open.[0-3|ALL|BYTE]
read-only, yes-no
Is the loop open? (1=yes, 0=no). Failsafe mode.
Note that OWFS uses 0 through 3 as the index and the datasheet uses 1
through 4.
STANDARD PROPERTIES
See the file man3/standard.3so.
ALARMS
None.
DESCRIPTION
See the file man3/description.3so.
mDI001
The mDI001 (3) is used to monitor digital lines for simple switching.
ADDRESSING
See the file man3/addressing.3so.
WEBSITE
http://www.cmciel.com/products-solutions/individual-products/4-channel-
fail-safe-digital-module-mdi001/
See the file man3/seealso.3so.
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille (paul.alfille@gmail.com)
OWFS Manpage 2003 mDI001(3)