DragonFly On-Line Manual Pages
DS2760(3) One-Wire File System DS2760(3)
NAME
DS2780 - Stand-alone Fuel Gauge IC
DS2788 - Stand-alone Fuel Gauge with LED Drivers
SYNOPSIS
Temperature Voltage Current Memory and Switch.
32 [.]XXXXXXXXXXXX[XX][/[ lock.[0-1|ALL] | memory |
pages/page.[0-1|ALL] | PIO | sensed | temperature | vbias | vis | volt
| volthours |
aef | chgtf | ds | learnf | pmod | porf | rnaop | sef | uven | uvf |
See the file man3/standard_mini.3so.
]]
Thermocouple
32 [.]XXXXXXXXXXXX[XX][/[ temperature | typeX/range_low |
typeX/range_high | typeX/temperature
FAMILY CODE
32
SPECIAL PROPERTIES
lock.[0-1|ALL]
read-write, yes-no
Lock either of the two eprom pages to prevent further writes.
Apparently setting lock is permanent.
memory
read-write, binary
Access to the full 256 byte memory range. Much of this space is
reserved or special use. User space is the page area.
See the DATASHEET for a full memory map.
pages/pages.[0-1|ALL]
read-write, binary Two 16 byte areas of memory for user application.
The lock property can prevent further alteration.
NOTE that the page property is different from the common OWFS
implementation in that all of memory is not accessible.
PIO
write-only, yes-no
Controls the PIO pin allowing external switching.
Writing "1" turns the PIO pin on (conducting). Writing "0" makes the
pin non-conducting. The logical state of the voltage can be read with
the sensed property. This will reflect the current voltage at the pin,
not the value sent to PIO
Note also that PIO will also be altered by the power-status of the
DS2680 See the datasheet for details.
sensed
read-only, yes-no
The logical voltage at the PIO pin. Useful only if the PIO property is
set to "0" (non-conducting).
Value will be 0 or 1 depending on the voltage threshold.
temperature
read-only, floating point
Temperature read by the chip at high resolution (~13 bits). Units are
selected from the invoking command line. See owfs(1) or owhttpd(1) for
choices. Default is Celsius.
Conversion is continuous.
vbias
read-write, floating point
Fixed offset applied to each vis measurement. Used for the volthours
value. Units are in Volts.
Range -2.0mV to 2.0mV
vis
read-only, floating point
Current sensor reading (unknown external resistor). Measures the
voltage gradient between the Vis pins. Units are in Volts
The vis readings are integrated over time to provide the volthours
property.
The current reading is derived from vis assuming the internal 25 mOhm
resistor is employed. There is no way to know this through software.
volt
read-only, floating point
Voltage read at the voltage sensor;. This is separate from the vis
voltage that is used for current measurement. Units are Volts
Range is between 0 and 4.75V
volthours
read-write, floating point
Integral of vis - vbias over time. Units are in volthours
THERMOCOUPLE
typeX/
directory
Thermocouple circuit using the DS2780 to read the Seebeck voltage and
the reference temperature. Since the type interpretation of the values
read depends on the type of thermocouple, the correct directory must be
chosen. Supported thermocouple types include types B, E, J, K, N, R, S
and T.
typeX/range_low typeX/ranges_high
read-only, flaoting point
The lower and upper temperature supported by this thermocouple (at
least by the conversion routines). In the globally chosen temperature
units.
typeX/temperature
read-only, floating point
Thermocouple temperature. Requires a voltage and temperature
conversion. Returned in globally chosen temperature units.
Note: there are two types of temperature measurements possible. The
temperature value in the main device directory is the reference
temperature read at the chip. The typeX/temperature value is at the
thermocouple junction, probably remote from the chip.
OBSCURE PROPERTIES
aef chgtf dc learnf pmod porf rnaop sef uven uvf
varies, yes-no
Bit flags corresponding to various battery management functions of the
chip. See the DATASHEET for details of the identically named entries.
In general, writing "0" corresponds to a 0 bit value, and non-zero
corresponds to a 1 bit value.
STANDARD PROPERTIES
See the file man3/standard.3so.
ALARMS
None.
DESCRIPTION
See the file man3/description.3so.
DS2780
The DS2780 (3) is a battery charging controller. It has elaborate
algorithms for estimating battery capacity.
A number of interesting devices can be built with the DS2780 including
thermocouples. Support for thermocouples in built into the software,
using the embedded thermister as the cold junction temperature.
ADDRESSING
See the file man3/addressing.3so.
DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS2780.pdf
http://pdfserv.maxim-ic.com/en/ds/DS2788.pdf
SEE ALSO
See the file man3/seealso.3so.
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille (paul.alfille@gmail.com)
OWFS Manpage 2003 DS2760(3)