DragonFly On-Line Manual Pages
DS2760(3) One-Wire File System DS2760(3)
NAME
DS2760, DS2761, DS2762 - High-Precision Li+ Battery Monitor
SYNOPSIS
Temperature Voltage and Current.
30 [.]XXXXXXXXXXXX[XX][/[ amphours | current | currentbias |
lock.[0-1|ALL] | memory | pages/page.[0-1|ALL] | PIO | sensed |
temperature | vbias | vis | volt | volthours |
cc | ce | coc | defaultpmod | defaultswen | dc | de | doc | mstr | ov |
ps | pmod | swen | uv |
See the file man3/standard_mini.3so.
]]
Thermocouple
30 [.]XXXXXXXXXXXX[XX][/[ temperature | typeX/range_low |
typeX/range_high | typeX/temperature ]]
Weather Station
30 [.]XXXXXXXXXXXX[XX][/[ WS603/temperature | WS603/wind_speed |
WS603/direction | WS603/volt |
WS603/LED/status | WS603/LED/control.ALL | WS603/LED/model |
WS603/calibrationwind_speed | WS603/calibration/direction |
WS603/light/intensity | WS603/light/threshold
FAMILY CODE
30
SPECIAL PROPERTIES
amphours
read-write, floating point
Accumulated amperage read by current sensor. Units are in Amp-hr
(Assumes internal 25mOhm resistor). Derived from volthours / Rinternal.
Formally amphours is the integral of current - currentbias over time.
current
read-only, floating point
Current reading. Units are in Amp (Assumes internal 25 mOhm resistor).
Derived from vis / Rinternal.
currentbias
read-write, floating point
Fixed offset applied to each current measurement. Used in the amphours
value. Assumes internal 25mOhm resistor. Units are Amp and range from
-.08A to .08A.
Derived from vbias / Rinternal.
lock.[0-1|ALL]
read-write, yes-no
Lock either of the two eprom pages to prevent further writes.
Apparently setting lock is permanent.
memory
read-write, binary
Access to the full 256 byte memory range. Much of this space is
reserved or special use. User space is the page area.
See the DATASHEET for a full memory map.
pages/pages.[0-1|ALL]
read-write, binary Two 16 byte areas of memory for user application.
The lock property can prevent further alteration.
NOTE that the page property is different from the common OWFS
implementation in that all of memory is not accessible.
PIO
write-only, yes-no
Controls the PIO pin allowing external switching.
Writing "1" turns the PIO pin on (conducting). Writing "0" makes the
pin non-conducting. The logical state of the voltage can be read with
the sensed property. This will reflect the current voltage at the pin,
not the value sent to PIO
Note also that PIO will also be altered by the power-status of the
DS2670 See the datasheet for details.
sensed
read-only, yes-no
The logical voltage at the PIO pin. Useful only if the PIO property is
set to "0" (non-conducting).
Value will be 0 or 1 depending on the voltage threshold.
temperature
read-only, floating point
Temperature read by the chip at high resolution (~13 bits). Units are
selected from the invoking command line. See owfs(1) or owhttpd(1) for
choices. Default is Celsius.
Conversion is continuous.
vbias
read-write, floating point
Fixed offset applied to each vis measurement. Used for the volthours
value. Units are in Volts.
Range -2.0mV to 2.0mV
vis
read-only, floating point
Current sensor reading (unknown external resistor). Measures the
voltage gradient between the Vis pins. Units are in Volts
The vis readings are integrated over time to provide the volthours
property.
The current reading is derived from vis assuming the internal 25 mOhm
resistor is employed. There is no way to know this through software.
volt
read-only, floating point
Voltage read at the voltage sensor;. This is separate from the vis
voltage that is used for current measurement. Units are Volts
Range is between 0 and 4.75V
volthours
read-write, floating point
Integral of vis - vbias over time. Units are in volthours
THERMOCOUPLE
typeX/
directory
Thermocouple circuit using the DS2760 to read the Seebeck voltage and
the reference temperature. Since the type interpretation of the values
read depends on the type of thermocouple, the correct directory must be
chosen. Supported thermocouple types include types B, E, J, K, N, R, S
and T.
typeX/range_low typeX/ranges_high
read-only, flaoting point
The lower and upper temperature supported by this thermocouple (at
least by the conversion routines). In the globally chosen temperature
units.
typeX/temperature
read-only, floating point
Thermocouple temperature. Requires a voltage and temperature
conversion. Returned in globally chosen temperature units.
Note: there are two types of temperature measurements possible. The
temperature value in the main device directory is the reference
temperature read at the chip. The typeX/temperature value is at the
thermocouple junction, probably remote from the chip.
WEATHER STATION
WS603
directory
Weather station from AAG electronica that includes temperature, wind
speed, wind direction, light sensor and LED lights.
WS603/temperature
read-only, floating-point
Uses the DS2760 temperature sensor. This is equivalent to the
temperature value. Again in the specificed temperature scale, default
Celsius.
WS603/wind_speed
read_only, floating-point
Readings from the anometer, scaled using the
WS603/calibration/wind_speed
WS603/direction
read_only, unsigned integer
Wind direction, using the following table
1 N
2 NNE
3 NE
4 NEE
5 E
6 EES
7 ES
8 ESS
9 S
10 SSW
11 SW
12 SWW
13 W
14 WWN
15 WN
16 WWN
Values are adjusted (internally) by the WS603/calibration/direction
property
WS603/volt
read-only, unsigned integer
Voltage value from the WS603 device. Units and significance is unclear.
WS603/calibration/wind_speed
read-write, unsigned integer
Value between 1 and 200 for wind speed scaling. Values on of this range
are ignored and the default value of 100 used.
WS603/calibration/direction
read-write, unsigned integer
Adjustment of wind direction. See datasheet.
WS603/light/intensity
read-only, unsigned integer
Uncalibrated value from an internal light sensor. Used for control of
LED display (daytime vs nighttime).
WS603/light/threshold
read-only, unsigned integer
Threshold for internal light sensor. Used for control of LED display
(daytime vs nighttime).
Value is set as value 4 of the array passed to WS603/LED/control
WS603/LED/status
read-only, unsigned integer
Status of LED lights intensities. See datasheet.
Value is set as values 2 and 3 of the array passed to WS603/LED/control
WS603/LED/model
read-only, unsigned integer
What factors control LED display. See datasheet.
Value is set as value 1 of the array passed to WS603/LED/control.ALL
WS603/LED/model
write-only, unsigned integer array of 4 values
Four integers sent to control LED display. All four values must be
sent, comma separated.
0 Light mode
1 Light status
2 Light level
3 Light threshold
OBSCURE PROPERTIES
cc ce coc dc de doc mstr ov pmod swen uv
varies, yes-no
Bit flags corresponding to various battery management functions of the
chip. See the DATASHEET for details of the identically named entries.
In general, writing "0" corresponds to a 0 bit value, and non-zero
corresponds to a 1 bit value.
defaultpmod defaultswen
read-write, yes-no
Default power-on state for the corresponding properties.
STANDARD PROPERTIES
See the file man3/standard.3so.
ALARMS
None.
DESCRIPTION
See the file man3/description.3so.
DS2760 DS2761 DS2762
The DS2760 (3) is a class of battery charging controllers. There are
minor hardware difference between the DS2760, DS2761 and DS2762 battery
chip, but they are indistiguishable to the software.
A number of interesting devices can be built with the DS276x including
thermocouples. Support for thermocouples in built into the software,
using the embedded thermister as the cold junction temperature.
For an explanation of the differences between the DS276x variants, see
Dallas Application Note 221.
ADDRESSING
See the file man3/addressing.3so.
DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS2760.pdf
http://pdfserv.maxim-ic.com/en/an/app221.pdf
http://www.aag.com.mx/aagusa/contents/en-
us/Description%20of%20WSV3%20Interface%20(1-wire).pdf
SEE ALSO
See the file man3/seealso.3so.
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille (paul.alfille@gmail.com)
OWFS Manpage 2003 DS2760(3)